Managing Hazard Assessment Hazard Control Resp Class Purify Elements Chart Search by Chemical

B2 - Constant-Flow Air-Line Respirator, Half-Mask

Constant-Flow Respirator with Comfo® Facepiece

   An air-line respirator with a half-mask facepiece. A 30" flexible breathing tube connects the facepiece to an air-flow control valve, which is clipped to a web support belt.
   The facepiece is made of hycar rubber designed to resist chemical attack, temperature extremes and facial oils. It features a cradle headband.
   Users may choose from devices designed to work with compressors capable of delivering air flow of either 10-15 psig (for use with 8-50` of air-line) or 35-40 psig ( for use with 8-300` of air-line). A choice of aluminum Snap-tite or steel Foster quick-disconnect fittings is available.
   Order MSA air-supply line separately.

    See Data Sheet 01-00-01

Constant-Flow Respirator with Comfo® Welder's Facepiece

   An air-line respirator with a special half-mask facepiece designed to fit under a welding helmet. The respirator's breathing tube connects the facepiece to an air-flow control valve fitting clipped to a web support belt.
   With the Low-Profile Comfo welder's facepiece, made of hycar rubber, the breathing tube is attached to the side.  A 90o elbow permits the breathing tube to be slung over the shoulder to avoid interference with the welder's protective headgear.
   Users may choose from devices designed to work with compressors capable of delivering air flow of either 10-15 psig (for use with 8-50` of air-line) or 35-40 psig (for use with 8-50` of air-line).  A choice of either aluminum Snap-tite or steel Foster quick-disconnect fittings is available.
   Order MSA air-supply line separately.

    See Data Sheet 01-00-0

Bottom_Bar

Mine Safety Appliances Company (MSA) makes no warranties, understandings or representations, whether expressed, implied, or statutory regarding this response respirator selector. MSA specifically disclaims any warranty for merchantability or fitness for a particular purpose. In no event shall MSA, or anyone else who has been involved in the creation, production or delivery of this respirator selector be liable for any direct, indirect, special, incidental or consequential damages arising out of the use of or inability to use this respirator selector or for any claim by any other party. ©MSA 2005